Automation Components, Inc. A/WPR2-100-M10-LCD

memberiso
" Not available to buy online? Want the lower wholesale price? Please send RFQ, we will respond immediately
Contact Name
Business Email
Company Name
Country
Quantity
Email

Leave Us A Message!

We`re not around but we still want to hear from you! Leave us a note:

SEND
EmailWhatsApp
*You can contact us directly on WhatsApp!
Specifications
Type
Paramete
Type
Paramete
Pressure Type
Differential
Package / Case
Module
Port Size
Male - 1/4" (6.35mm) NPT
Qualification
-
Grade
-
Maximum Pressure
200PSI (1378.95kPa)
Mounting Type
-
Features
Temperature Compensated
Output
0V ~ 5V, 0V ~ 10V, 4mA ~ 20mA
Port Style
Threaded
Supplier Device Package
-
Applications
Industrial Automation
Voltage - Supply
24VAC, 16 ~ 36VDC
Termination Style
Cable with Connector
Accuracy
±1%
Operating Temperature
-40°C ~ 125°C
Operating Pressure
100PSI (689.48kPa)
Output Type
Analog Current, Analog Voltage
Overview

DESCRIPTION



· The ACI WPR2 Series Remote Wet to Wet Differential Pressure Transmitter reduces installation time and offers mounting flexibility, often eliminating the need for additional plumbing and manifolds.

· It can be ordered with standard CMP rated PVC cable or metal clad cable, which provides end-to-end protection with flexible metal conduit, resistant to abrasions and cuts, and constructed with corrosion-resistant 304 stainless steel.

· The WPR2 accurately measures wet media pressures in various applications, including monitoring pumps, measuring pressure across filters, heat exchangers, and compressors.

· Features dual remote sensors with a ceramic capacitive sensing element and a stainless steel diaphragm compatible with liquids, gases, and refrigerants suitable with 304L stainless steel.

· The pressure transducers are equipped with ¼”-18 NPT male (304 stainless steel) fittings.

· The enclosure can be reconfigured between three additional ranges and outputs of 4 to 20 mA, 0 to 5 VDC, or 0 to 10 VDC (default).

· Measures both uni or bi-directional pressure ranges as low as 3 psi and as high as 300 psi, depending on the unit.

· Includes a push button auto zero function for remote calibration and an LCD option to display pressure values, differential pressure, "OVR", "ERROR", and "ZERO".



FEATURES



· Supply Voltage: 4-20 mA Output: 18-36 VDC (250 Ohm Load max.) / 20-36 VDC (500 Ohm Load max.) / 24 VAC (+/-10%) 50/60 Hz 0-5 VDC / 0-10 VDC Output: 16-36 VDC / 24 VAC (+/- 10%) 50/60 Hz.

· Supply Current: 4-20 mA Output: 24 mA minimum | 0-5 VDC / 0-10 VDC Outputs: 6 mA minimum.

· Output Signals: 2-wire: Linear 4-20 mA DC Current (Field Selectable) | 3-wire: 0-5 VDC; 0-10 VDC (Default) & 4-20 mA (Field Selectable).

· Response Time (0-100% FSO): 8 seconds | Output Update Rate: 1 second | Output Load Resistance: 4 to 20 mA : 500 ohms maximum | 0-5 VDC / 0-10 VDC: 5K ohms minimum.

· Field Selectable Ranges: See “Ordering Grid” on back of product data sheet | Warm Up Time: 15 minutes (wait 15 minutes before zeroing).

· Accuracy: ±1.0% FSO (Three Highest Ranges) | ±1.5% FSO (Lowest Range) | Thermal Effects: ±2.0% FSO from 32-140°F (0-60°C).

· Operating Temperature: Transducer: -40 to 257°F (-40 to 125°C) | Electronics/Housing/Cables: 32-167°F (0-75°C).

· Compensated Temperature Range: 32 to 140°F (0 to 60°C) | Storage Temperature: -13 to 176°F (-25 to 80°C).

· Operating Humidity: 10 to 90% RH, non-condensing | Proof Pressure: WPR2-30: 60 PSI | WPR2-100: 200 PSI | WPR2-300: 600 PSI.

· Burst Pressure: WPR2-30: 300 PSI | WPR2-100: 1000 PSI | WPR2-300: 3000 PSI.

· Media Types: Any gas or liquid compatible with 304L or 316L Stainless Steel | Process Fitting Material: 304 SS | Process Fitting Size: 1/4" - 18 NPT Male; Pressure Snubber included for light oils/water.

· Recommend Torque Specification: 150 lbs-in (16.95 Nm) | Transducer Cable Rating | Connector Type: Type CMP - Plenum Rated (UL Standard 444), NEC Article 800 | IP65 at the sensors Packard Connector.

· Metal Clad Rating: Continuously interlocked Type 304 Stainless Steel core | Enclosure Material | Flammability Rating: Flame Retardant PC | PBT Alloy | UL94V-0 | Enclosure Rating: NEMA 4X/IP66.

· Approvals: CE, RoHS2, WEEE, Reach | Product Dimensions (L x W x D): 5.30" x 5.07" x 3.00" (13.46 cm x 12.88 cm x 7.62 cm).

· Product Weight: A/WPR2 (0-xxx psid)-10’: 2.1 lbs (0.953 kg) | A/WPR2(0-xxx psid)-10’-LCD: 2.2 lbs (0.998 kg) | A/WPR2 (0-xxx psid)-20’: 2.4 lbs (1.09 kg) | A/WPR2 (0-xxx psid)-20’-LCD: 2.5 lbs (1.138 kg) | A/WPR2 (0-xxx psid)-40’: 3 lbs (1.363 kg) | A/WPR2 (0-xxx psid)-40’-LCD: 3.1 lbs (1.41 kg).



APPLICATIONS



· Monitoring Pumps, Compressors, Filters, Heat Exchangers, Flow.

· The WPR2 Series is covered by ACI’s Five (5) Year Limited Warranty, details of which can be found in the front of ACI’s Sensors & Transmitters catalog and on ACI’s website, workaci.com.

Shopping Guide
Purchase

No need to register to order from JMChip Electronics, but signing in lets you track your order like a pro. Give it a try for a smoother shopping ride.

Means

Easy peasy! Pay your way with PayPal, Credit Card, or wire transfer in USD. We've got you covered.

RFQ(Request for Quotations)

Get the freshest prices and stock updates by asking for a quote! Our sales team will shoot you an email within a day. It's that simple.

IMPORTANT NOTICE

1. Look out for your order details in your inbox! (If it's missing, check the spam folder just in case.)

2. Our sales manager will double-check the order and keep you posted on any price or stock changes. No worries, we've got you covered. 

picture_01

Shipping Rate

We ship orders once a day around 5 p.m., except Sunday. Once shipped, the estimated delivery time depends on the courier company you choose, usually 5-7 working days.

picture_02

Shipping Methods

We provide DHL, FedEx, UPS, EMS, SF Express, and Registered Air Mail international shipping.

pdf
picture_03

Payment

You can pay the orders on the website directly or pay by wire transfer offline. We support: Paypal、VISA、Credit Card.

pdfpdfpdfpdf