Specifications
Type
Paramete
Type
Paramete
Number of Characters Per Row
-
Communications
-
Display Type
-
Mounting Type
-
Number of Inputs and Type
-
Number of Outputs and Type
-
Expandable
-
Voltage - Supply
-
Features
-
Memory Size
-
Overview

Opto 22 GRV-OACIS-12 12-250 VAC Output Module - Complete Specification Sheet


1. Basic Product Information

表格


ItemDetailed Specification
Part NumberGRV-OACIS-12
Product Seriesgroov 12–250 VAC Output Modules
Product CategoryI/O Modules (groov EPIC® System Compatible)
Product DescriptionAC digital output module, 12 channels, 12–250 VAC, with channel-to-channel isolation and on/off only functionality
Core ApplicationSwitching up to 12 separate AC loads; compatible with groov EPIC® (Edge Programmable Industrial Controller) system; ideal for industrial automation, process control, and remote monitoring
Key System IntegrationWired directly to field devices (sensors/actuators); translates electrical signals to digital language for local network or cloud data use
StatusActive
ManufacturerOpto 22
Factory TestingTwice before shipment
WarrantyLifetime Guarantee

2. Core Features


  • Channel Configuration: 12 independent channels with channel-to-channel isolation (no shared field signal connections internally)
  • Operational Mode: On/off only functionality (cost-effective for simple switching requirements)
  • Switching Protection: Zero voltage turn-on and zero current turn-off to minimize transients; 300V transient protection between field signals and logic side
  • User Interface: Module cover with LED (module health indicator) and touch-sensitive pad (triggers module info display on groov EPIC® processor)
  • Mechanical Design: Swinging two-position cover (accommodates thick wires) with dead-front design; top-mounted removable spring-clamp terminal connector
  • Installation Flexibility: Hot-swappable (install/remove without powering down); self-identifying (auto-communicates with chassis upon mounting)
  • Environmental Suitability: UL Hazardous Locations approved and ATEX compliant

3. Electrical Specifications

表格


ParameterRatingNotes
Line Voltage Range12–250 VACOperating voltage for connected AC loads
Current Rating (per channel)0.5 AMaximum current per channel
Minimum Load Current20 mARequired minimum load for stable operation
Output Voltage Drop1 VVoltage drop when channel is active
Off-state Leakage Current (60 Hz)1.25 mA @ 240 VAC; 0.7 mA @ 120 VACLeakage at nominal voltage
Peak Blocking Voltage500 VMaximum blocking voltage capability
Operating Frequency40 to 60 Hz, 400 HzCompatible AC frequency ranges
Turn-on Time≤ 1/2 cycle (zero crossing)Zero voltage switching
Turn-off Time≤ 1/2 cycle (zero crossing)Zero current switching
TPO PeriodN/ANot supported (on/off only functionality)
Isolation (Field-to-Logic)300 V working; 1500 V transient (1 minute)Protection between field and logic circuits
Isolation (Channel-to-Channel)300 V workingIndependent isolation between channels
Chassis Power Consumption1.3 WPower drawn from groov EPIC chassis
Recommended Over-Current Protection2 A 250 VAC per channel; 6 A 250 VAC commonFast-acting fuse or circuit breaker

4. Mechanical & Physical Specifications


4.1 Dimensions (Imperial/Metric)

表格


DimensionCover in Lower PositionCover in Higher Position
Overall Height6.75 in / 171.5 mm7.25 in / 184.2 mm
Length5.42 in / 137.8 mm5.92 in / 150.5 mm
Width0.77 in / 19.4 mm0.77 in / 19.4 mm
Wireway Height5.42 in / 137.8 mm6.09 in / 154.8 mm

4.2 Terminal & Wiring Specifications

表格


ItemSpecification
Wire Size28–14 AWG
Wire Strip Length0.315–0.354 inches (8–9 mm)
Terminal TypeSpring-clamp terminals
Terminal ConnectorRemovable (held by captive retention screw)
Connector Screw Torque2.5 in-lb (0.28 N-m)
Hold-down Screw Torque3.5 in-lb (0.4 N-m)
Wiring Tool RequirementsFlathead screwdriver (2.5 mm x 0.4 mm tip) or groov spring-clamp terminal tool (GRVTEX-SCTOOL)

4.3 Environmental Ratings

表格


ParameterRange
Operating Temperature-20 °C to +70 °C
Storage Temperature-40 °C to +85 °C
Relative Humidity (Non-Condensing)5–95%
MTBF (Minimum, 25 °C)1.2 Mhrs

5. Software & Firmware Requirements

表格


RequirementMinimum Version
groov EPIC Firmware1.0.0
PAC Project10.0000
CODESYS Library Package1.0.0.0

6. Agency Approvals & Compliance

表格


StandardStatus/Details
UL/cULListed (Class 1, Div 2)
CE DirectivesATEX (Category 3, Zone 2), Low Voltage, EMC
RoHSCompliant
DFARSCompliant
CB SchemeCompliant
UKCACompliant
Note for Hazardous LocationsMust be mounted in an enclosure meeting National Electrical Code (ANSI/NFPA 70) and ANSI/ISA-61010-1 (82.02.01) requirements

7. Pinout & Wiring Instructions


7.1 Key Wiring Notes


  • All loads require user-supplied fuses (per over-current protection specs)
  • Channels are isolated; no shared field connections
  • Terminal connector features clamp release holes and field wiring holes for spring-clamp operation

7.2 Channel Pinout (Internal Pin → External Wiring)

表格


ChannelInternal PinsExternal Connection
Channel 02, 3AC Load (Line or Common)
Channel 14, 5AC Load (Line)
Channel 26, 7AC Load (Line)
Channel 38, 9AC Load
Channel 410, 11AC Load (Line)
Channel 512, 13AC Load (Line)
Channel 615, 16AC Load (Line or Common)
Channel 717, 18AC Load
Channel 819, 20AC Load (Line)
Channel 921, 22AC Load (Line)
Channel 1023, 24AC Load (Line)
Channel 1125, 26AC Load (Line)
Unused Pins14No connection

7.3 Wiring Procedures


Inserting Wires


  1. Orient module/terminal connector to match wiring diagram.
  2. Secure module or terminal connector (clamp if detached).
  3. Insert tool into clamp release hole (press against side furthest from terminal numbers) and press straight down until bottom is reached.
  4. Insert stripped wire into field wiring hole.
  5. Pull out tool to engage spring clamp.
  6. Test wire security by gentle tugging.

Removing Wires


  1. Insert tool into clamp release hole and press straight down.
  2. Pull wire out of field wiring hole.
  3. Remove tool to reset spring clamp.

8. Mounting & Unmounting Instructions


8.1 Mounting Steps


  1. De-energize field devices connected to the terminal connector.
  2. Orient groov EPIC chassis with module connector numbers right-side up (0 on left).
  3. Hold module at 45° angle, align alignment tab with chassis slot.
  4. Pivot module down to snap into chassis connector.
  5. Lift module cover, tighten hold-down screw (3.5 in-lb torque).
  6. Install terminal connector (if not pre-installed) and tighten connector screw (2.5 in-lb torque).
  7. Wire field devices per pinout instructions.
  8. Close module cover (adjust to higher position for thick wires if needed).
  9. Restore power (if previously powered down).

8.2 Unmounting Steps


  1. De-energize field devices connected to the terminal connector.
  2. Lift module cover to access wiring and hold-down screw.
  3. Remove wiring:
  4. Remove hold-down screw.
  5. Pull up on module grip tab to release from chassis connector, then remove module.
  6. Restore power (if applicable).

9. Module Parts & Functions

表格


Part NameFunction
Module LEDIndicates module health (e.g., solid blue = normal; blinking blue = info displayed on EPIC processor)
Touch-sensitive PadTriggers module info (specs, wiring diagram) on groov EPIC processor (press for ~2 seconds)
Two-position HingeAdjusts cover height for wire clearance
WirewaySpace under cover for wiring; expanded with higher hinge position
Catch TabSecures cover in open position for wiring access
Strain Relief TabSecures wire bundles (via zip tie) to prevent strain on terminals
Alignment TabGuides module into chassis slot during mounting
Module Grip TabFacilitates module removal from chassis
Discrete Channel IndicatorsDisplays on/off status of each channel


Shopping Guide
Purchase

No need to register to order from JMChip Electronics, but signing in lets you track your order like a pro. Give it a try for a smoother shopping ride.

Means

Easy peasy! Pay your way with PayPal, Credit Card, or wire transfer in USD. We've got you covered.

RFQ(Request for Quotations)

Get the freshest prices and stock updates by asking for a quote! Our sales team will shoot you an email within a day. It's that simple.

IMPORTANT NOTICE

1. Look out for your order details in your inbox! (If it's missing, check the spam folder just in case.)

2. Our sales manager will double-check the order and keep you posted on any price or stock changes. No worries, we've got you covered. 

picture_01

Shipping Rate

We ship orders once a day around 5 p.m., except Sunday. Once shipped, the estimated delivery time depends on the courier company you choose, usually 5-7 working days.

picture_02

Shipping Methods

We provide DHL, FedEx, UPS, EMS, SF Express, and Registered Air Mail international shipping.

pdf
picture_03

Payment

You can pay the orders on the website directly or pay by wire transfer offline. We support: Paypal、VISA、Credit Card.

pdfpdfpdfpdf